TEMPERGARD 2000

Tempergard 2000

HIGH-TEMPERATURE LEAD WIRE

Ratings/Approvals:

  • 450°C – 600 Volts – Continuous temperature rating under normal service conditions
  • 450°C – 600 Volts – Temporary temperature rating for short periods
  • Maintains circuit integrity 2.5 hrs under ICEA T-29-520
  • 210,000 BTU/hr Vertical Cable Tray Flame Test
  • RoHS Compliant

Construction:

  • Conductors
    • 18 AWG – 2 AWG
    • Stranded nickel-coated copper – 27%
      (Other conductor materials available)
  • Insulating System
    • Reinforced mica glass tape
    • Fiberglass braid with high temperature finish
    • Fire barrier tape wraps
    • PTFE moisture and fluid barrier
  • Outer Covering
    • Braided fiberglass with high temperature finish
  • Standard Color Coding
    • Black or Natural

Characteristics:

  • Moisture, oil, fluid, and abrasion resistant
  • Composed of flame-impervious inorganic materials
  • Withstands mechanical abuse
  • Not recommended for outdoor use

SPECIFICATIONS

Tempergard 2000

HIGH-TEMPERATURE LEAD WIRE

Download Tempergard 2000 Specs

Tempergard 2000 450C(538C)/600V

Part No.Awg. Size# StrandsOuter Dia. inchesOuter Dia. mmWgt. (lbs/Mft)Wgt (kg/km)Min. Bend Radius (in)ULCSA
BKT18C01618160.1674.241118.611.34N/AN/A
BKT16C02616260.1794.551523.431.43N/AN/A
BKT14C04114410.1894.802231.431.51N/AN/A
BKT12C06512650.2135.413140.141.70N/AN/A
BKT10C105101050.2666.768366.912.13N/AN/A
BKT08C13381330.3168.037995.192.53N/AN/A
BKT06C13361330.3579.07113133.622.86N/AN/A
BKT04C13341330.40810.36167183.513.26N/AN/A
BKT02C13321330.48212.24259279.703.86N/AN/A

Standard conductor: Nickel Plated Copper – 27%
Consult factory for alternative conductor and stranding options.