VW-1 DuraFlex® 450
HIGH-TEMPERATURE WIRE
Ratings/Approvals:
- 450°C – 300 Volts – UL 5334 / 5128 / CSA AWM I A/B FT1
- 450°C – 600 Volts – UL 5335 / 5107 / CSA AWM I A/B FT1
- VW-1 Flame Rated
Construction:
- Conductors
- 24 AWG – 14 AWG (300 Volts)
- 22 AWG – 8 AWG (600 Volts)
- Stranded nickel-coated copper – 27%
(Other conductor materials available)
- Insulating System
- Mica glass composite
- Outer Covering
- Fiberglass braid with high temperature finish
- Standard Color Coding
- Natural and Solid Colors
- Colored Tracers
Characteristics:
- Outperforms UL 5128/5107 MGT products:
- Unique insulation system offers outstanding heat-aged flexibility for longer service life.
- Passes UL 2X mandrel test after heat aging (UL 5128/5107 is 3X mandrel).
- Excellent cutting and stripping characteristics, making it ideal for high volume manufacturing and assembly.
- Provides dimensional consistency and uniformity.
- Resists braid pushback.
- Withstands mechanical abuse.
SPECIFICATIONS
VW-1 DuraFlex® 450
HIGH-TEMPERATURE WIRE
Download VW-1 DuraFlex® 450 Specs
DuraFlex® 450C/300V
Part No. | Awg. Size | # Strands | Outer Dia. inches | Outer Dia. mm | Wgt. (lbs/Mft) | Wgt (kg/km) | Min. Bend Radius (in) | UL | CSA |
---|---|---|---|---|---|---|---|---|---|
DGT24C007 | 24 | 7 | 0.068 | 1.73 | 4 | 6.37 | 0.54 | 5334/5128 | AWM I A/B FT1 |
DGT22C007 | 22 | 7 | 0.081 | 2.06 | 6 | 8.83 | 0.65 | 5334/5128 | AWM I A/B FT1 |
DGT20C010 | 20 | 10 | 0.088 | 2.24 | 8 | 11.19 | 0.70 | 5334/5128 | AWM I A/B FT1 |
DGT18C016 | 18 | 16 | 0.096 | 2.44 | 10 | 14.51 | 0.77 | 5334/5128 | AWM I A/B FT1 |
DGT16C026 | 16 | 26 | 0.110 | 2.79 | 14 | 20.43 | 0.88 | 5334/5128 | AWM I A/B FT1 |
DGT14C041 | 14 | 41 | 0.126 | 3.20 | 20 | 29.33 | 1.01 | 5334/5128 | AWM I A/B FT1 |
DuraFlex® 450C/600V
Part No. | Awg. Size | # Strands | Outer Dia. inches | Outer Dia. mm | Wgt. (lbs/Mft) | Wgt (kg/km) | Min. Bend Radius (in) | UL | CSA |
---|---|---|---|---|---|---|---|---|---|
DHT22C007 | 22 | 7 | 0.098 | 2.49 | 7 | 11.01 | 0.78 | 5335/5107 | AWM I A/B FT1 |
DHT20C010 | 20 | 10 | 0.108 | 2.74 | 10 | 14.53 | 0.86 | 5335/5107 | AWM I A/B FT1 |
DHT18C016 | 18 | 16 | 0.120 | 3.05 | 13 | 19.05 | 0.96 | 5335/5107 | AWM I A/B FT1 |
DHT16C026 | 16 | 26 | 0.134 | 3.40 | 17 | 25.54 | 1.07 | 5335/5107 | AWM I A/B FT1 |
DHT14C041 | 14 | 41 | 0.150 | 3.81 | 23 | 34.62 | 1.20 | 5335/5107 | AWM I A/B FT1 |
DHT12C065 | 12 | 65 | 0.170 | 4.32 | 33 | 49.22 | 1.36 | 5335/5107 | AWM I A/B FT1 |
DHT10C105 | 10 | 105 | 0.211 | 5.36 | 52 | 77.25 | 1.69 | 5335/5107 | AWM I A/B FT1 |
DHT08C133 | 8 | 133 | 0.261 | 6.63 | 77 | 114.21 | 2.09 | 5335/5107 | AWM I A/B FT1 |
Standard conductor: Nickel Plated Copper – 27%