Braidless Silicone 150
HIGH-TEMPERATURE LEAD WIRE
Ratings/Approvals:
- 150°C – 600 Volts – UL Style 3212, 3213, 3214 / CSA AWM I A/B FT2
- VW-1 Rated
- RoHS Compliant
Construction:
Conductors
22 AWG – 4/0 AWG
Stranded tinned copper
(Other conductor materials available. Please consult factory.)
Insulating System
Extruded Silicone Rubber
Standard Color Coding
Available in Colors or Striped Combinations
Characteristics:
- Silicone formulations suitable for UV, ozone, moisture exposure
- Not suited for immersed applications
- Suitable for applications from 150°C to -60°C
- Superior flexibility
SPECIFICATIONS
Braidless Silicone 150
HIGH-TEMPERATURE LEAD WIRE
Download Braidless Silicone 150 Specs
Braidless Silicone 150C/600V
Part No. | Temp Rating | Voltage Rating | Awg. Size | # Strands | Final O.D. (in) | Final O.D. (mm) | Wgt. (lbs/Mft) | Wgt. (kg/km) | Min. Bend Radius (in) | UL | CSA |
---|---|---|---|---|---|---|---|---|---|---|---|
HDA22T007 | 150C | 600V | 22 | 7 | 0.123 | 3.12 | 8.29 | 12.34 | 0.98 | 3212 | AWM I A/B FT2 |
HDA20T007 | 150C | 600V | 20 | 7 | 0.126 | 3.20 | 10.08 | 15.00 | 1.01 | 3212 | AWM I A/B FT2 |
HDA18T016 | 150C | 600V | 18 | 16 | 0.139 | 3.53 | 12.64 | 18.81 | 1.11 | 3212 | AWM I A/B FT2 |
HDA16T026 | 150C | 600V | 16 | 26 | 0.149 | 3.78 | 16.48 | 24.53 | 1.19 | 3212 | AWM I A/B FT2 |
HDA14T041 | 150C | 600V | 14 | 41 | 0.164 | 4.17 | 22.35 | 33.26 | 1.31 | 3212 | AWM I A/B FT2 |
HDA12T065 | 150C | 600V | 12 | 65 | 0.181 | 4.60 | 31.33 | 46.63 | 1.45 | 3212 | AWM I A/B FT2 |
HDA10T105 | 150C | 600V | 10 | 105 | 0.204 | 5.18 | 45.34 | 67.48 | 1.63 | 3212 | AWM I A/B FT2 |
HDA08T133 | 150C | 600V | 8 | 133 | 0.285 | 7.24 | 76.81 | 114.31 | 2.28 | 3213 | AWM I A/B FT2 |
HDA06T133 | 150C | 600V | 6 | 133 | 0.331 | 8.41 | 114.23 | 170.00 | 2.65 | 3213 | AWM I A/B FT2 |
HDA04T133 | 150C | 600V | 4 | 133 | 0.371 | 9.42 | 154.69 | 230.22 | 2.97 | 3213 | AWM I A/B FT2 |
HDA02T259 | 150C | 600V | 2 | 259 | 0.436 | 11.07 | 233.63 | 347.70 | 3.49 | 3213 | AWM I A/B FT2 |
HDA01T259 | 150C | 600V | 1 | 259 | 0.507 | 12.88 | 301.13 | 448.15 | 4.06 | 3214 | AWM I A/B FT2 |
HDAX1T259 | 150C | 600V | 1/0 | 259 | 0.562 | 14.27 | 381.97 | 568.46 | 4.50 | 3214 | AWM I A/B FT2 |
HDAX2T259 | 150C | 600V | 2/0 | 259 | 0.608 | 15.44 | 470.08 | 699.59 | 4.86 | 3214 | AWM I A/B FT2 |
HDAX3T259 | 150C | 600V | 3/0 | 259 | 0.657 | 16.69 | 579.96 | 863.12 | 5.26 | 3214 | AWM I A/B FT2 |
HDAX4T259 | 150C | 600V | 4/0 | 259 | 0.717 | 18.21 | 718.38 | 1069.12 | 5.74 | 3214 | AWM I A/B FT2 |
Standard conductor: Tinned Copper.
Consult factory for alternative conductor and stranding options.
All dimensions listed above are nominal
Compliance: UL Listed File No. E22244. CSA Certfied File No. LL13427 or LL80670