VW-1 SIL-A-BLEND® 200

VW-1 Sil-A-Blend® 200

HIGH-TEMPERATURE LEAD WIRE

Ratings/Approvals:

  • 200°C – 600 Volts – UL Style 3512/3604 / CSA AWM I A/B FT2/FT1
  • UL VW-1 Flame Rated
  • RoHS compliant

Construction:

  • Conductors
    • 22 AWG – 8 AWG
    • Stranded tinned copper or nickel-plated copper
      (Other conductor materials available)
  • Insulating System
    • Composite Extruded Silicone Rubber with intermediate fiberglass reinforcement
    • Separator tape between conductor and silicone on select sizes (Not shown in illustration)
  • Standard Color Coding
    • Available in Colors

Characteristics:

  • Outperforms Braided Silicone products
    • Eliminates braid fraying, flowering, and shrink back
    • Virtually eliminates skin irritation
    • Reduces airborne fiberglass contaminants traditionally found in high volume processing
    • Superior flexibility
    • Color stable at elevated temperatures
    • LSZH – Low smoke, zero halogen
    • Suitable for varnish dip and bake applications
    • Smaller OD
  • Silicone formulations suitable for UV, ozone, moisture exposure
  • Not suited for immersed applications
  • Suitable for applications to -60°C

150°C version with flexible stranded conductor is available. (consult factory)

Recommended replacement for glass braided silicone

SPECIFICATIONS

VW-1 Sil-A-Blend® 200

HIGH-TEMPERATURE LEAD WIRE

Download VW-1 Sil-A-Blend® 200 Specs

VW-1 Sil-A-Blend® 200C/600V

Part No.Temp RatingVoltage RatingAwg. Size# StrandsFinal O.D. (in)Final O.D. (mm)Wgt. (lbs/ Mft)Wgt. (kg/km)Min. Bend Radius (in)ULCSA
NVW22P007200C600V22 NPC 2%70.0992.516.539.720.793512/3604AWM I A/B FT2
NVW20P007200C600V20 NPC 2%70.1082.748.1912.190.863512/3604AWM I A/B FT1
NVW18T007200C600V1870.1193.0210.7516.000.953512/3604AWM I A/B FT1
NVW16T007200C600V1670.1303.3014.3921.421.043512/3604AWM I A/B FT1
NVW14T007200C600V1470.1423.6119.0728.381.143512/3604AWM I A/B FT1
NVW12T019200C600V12190.1604.0628.5942.551.283512/3604AWM I A/B FT1
NVW10T019200C600V10190.2125.3847.1970.231.703512/3604AWM I A/B FT1
NVW08T061200C600V8610.2416.1270.58105.041.933512/3604AWM I A/B FT1

Standard conductor: Tinned Copper or Nickel Plated Copper (2%) as designated
Consult factory for alternative conductor and stranding options.

All dimensions listed above are nominal
Compliance: UL Listed File No. E22244. CSA Certfied File No. LL13427 or LL80670