Radix Wire & Cable Contact Us
Product
VW-1 DuraBlend 200

VW-1 DuraBlend® 200

HIGH-TEMPERATURE LEAD WIRE

Ratings/Approvals:

  • 200°C - 600 Volts - UL Style 3772 / CSA AWM I A/B FT2
  • 200°C - 1000 Volts - UL Style 3788 / CSA AWM I A/B FT2
  • UL VW-1 Flame Rated

Construction:

  • Conductors
    • 22 AWG - 4/0 AWG (600V, 1000V)
    • Stranded tinned copper or nickel-plated copper(Other conductor materials available)
  • Insulating System
    • Separator tape between conductor and silicone on sizes 10awg to 4/0 on UL Style 3788 only. (Not shown in illustration)
    • Composite Extruded Silicone Rubber with intermediate fiberglass einforcement
  • Standard Color Coding
    • Available in Colors or Striped Combinations

Characteristics:

  • Outperforms Braided Silicone products:
    • Smaller diameter, lighter weight, tighter bend radius
    • Intermediate fiberglass reinforcement
    • Eliminates braid fraying, flowering and shrink back
    • Virtually eliminates dermatitis
    • Significantly reduces airborne fiberglass contaminates traditionally found in high volume processing
    • Superior flexibility
    • Color stable at elevated temeratures
    • LSZH: Low Smoke Zero Halogen
  • Silicone formulations suitable for UV, ozone or moisture exposure
  • Not suited for liquid immersed applications
  • Suitable for applications to -60°C

Specifications

VW-1 DuraBlend® 200

HIGH-TEMPERATURE LEAD WIRE
VW-1 DuraBlend<sup>®</sup> 200
DuraBlend® 200C/600V
Part No. Awg. Size # Strands Outer Dia. inches Outer Dia. mm Wgt (lbs/Mft) Wgt (kg/km) Min. Bend Radius (in) UL CSA
NPA22P007 22 7 0.080 2.03 5 7.07 0.64 3772 AWM I A/B FT2
NPA20P007 20 7 0.087 2.21 6 8.99 0.70 3772 AWM I A/B FT2
NPA18T007 18 7 0.096 2.44 8 12.25 0.77 3772 AWM I A/B FT2
NPA16T007 16 7 0.108 2.74 12 17.37 0.86 3772 AWM I A/B FT2
NPA14T007 14 7 0.121 3.07 16 24.09 0.97 3772 AWM I A/B FT2
NPA12T019 12 19 0.138 3.51 25 37.41 1.10 3772 AWM I A/B FT2
NPA10T019 10 19 0.161 4.09 38 56.60 1.29 3772 AWM I A/B FT2
NPA14P041 14 NPC 2% 41 0.121 3.07 16 24.09 0.97 3772 AWM I A/B FT2
NPA12P065 12 NPC 2% 65 0.138 3.51 25 37.41 1.10 3772 AWM I A/B FT2
DuraBlend® 200C/600V/1000V
Part No. Awg. Size # Strands Outer Dia. inches Outer Dia. mm Wgt (lbs/Mft) Wgt (kg/km) Min. Bend Radius (in) UL CSA
NQA18T007 18 7 0.102 2.59 9 13.01 0.82 3772/3788 AWM I A/B FT2
NQA16T007 16 7 0.114 2.90 12 18.23 0.91 3772/3788 AWM I A/B FT2
NQA14T007 14 7 0.129 3.28 18 26.33 1.03 3772/3788 AWM I A/B FT2
NQA12T019 12 19 0.146 3.71 26 38.66 1.17 3772/3788 AWM I A/B FT2
NQA10T019 10 19 0.170 4.32 39 58.07 1.36 3772/3788 AWM I A/B FT2
NQA08T061 8 61 0.212 5.38 63 94.41 1.70 3772/3788 AWM I A/B FT2
NQA06T084 6 84 0.313 7.95 106 157.47 2.50 3772/3788 AWM I A/B FT2
NQA04T133 4 133 0.356 9.04 158 235.47 2.85 3772/3788 AWM I A/B FT2
NQA02T259 2 259 0.427 10.85 243 362.04 3.42 3772/3788 AWM I A/B FT2
NQA01T259 1 259 0.499 12.67 316 470.13 3.99 3772/3788 AWM I A/B FT2
NQAX1T259 1/0 259 0.544 13.82 371 552.23 4.35 3772/3788 AWM I A/B FT2
NQAX2T259 2/0 259 0.590 14.99 458 681.91 4.72 3772/3788 AWM I A/B FT2
NQAX3T259 3/0 259 0.639 16.23 567 843.89 5.11 3772/3788 AWM I A/B FT2
NQAX4T259 4/0 259 0.699 17.75 704 1048.02 5.59 3772/3788 AWM I A/B FT2

Standard conductor: Tinned Copper(Standard conductor for 20-22 AWG ONLY: Nickel Plated Copper - 2%)
Consult factory for alternative conductor and stranding options.

WE HAVE THE SOLUTION.

Radix’s team of technicians, engineers and researchers is committed to being innovators in the arena of high temperature wire and high temperature cable. Collectively we are on the tireless quest to provide the thinnest possible cable and wire while maintaining the highest possible performance.

We can help you find the wire and cable solution best suited for your application – just get in touch.

Our High Performance Cable And Wire Knowledge Is Yours, Trust Radix.