VW-1 DuraBlend 200

VW-1 DuraBlend® 200

HIGH-TEMPERATURE WIRE

Ratings/Approvals:

200°C – 300 Volts – UL Style 3919 / 3586 / CSA AWM I A/B FT2
200°C – 600 Volts – UL Style 3772 / CSA AWM I A/B FT1
200°C – 1000 Volts – UL Style 3788 / CSA AWM I A/B FT1
UL VW-1 Flame Rated
RoHS Compliant

Construction:

Conductors
22 AWG – 16 AWG (300V)
22 AWG – 4/0 AWG (600V, 1000V)
Stranded tinned copper or nickel-plated copper
(Other conductor materials available)

Insulating System
Composite Extruded Silicone Rubber with intermediate fiberglass reinforcement
Separator tape between conductor and silicone on sizes 10awg to 4/0 on UL Style 3788 only. (Not shown in illustration)

Standard Color Coding
Available in Colors or Striped Combinations

Characteristics:

  • Lead wire
  • Outperforms Braided Silicone products:
    • Smaller diameter, lighter weight, tighter bend radius
    • Superior flexibility
    • Eliminates braid fraying, flowering and shrink back
    • Virtually eliminates skin irritation
    • Significantly reduces airborne fiberglass contaminates traditionally found in high volume processing
    • Color stable at elevated temperatures
    • LSZH: Low Smoke Zero Halogen
  • Silicone formulations suitable for UV, ozone or moisture exposure
  • Not suited for liquid immersed applications
  • Suitable for applications to -60°C
  • PFAS-Free

Recommended replacement for glass braided silicone

SPECIFICATIONS

VW-1 DuraBlend® 200

HIGH-TEMPERATURE WIRE

Download VW-1 DuraBlend® 200 Specs

VW-1 DuraBlend® 200C/300V

Part No.Temp
Rating
Voltage
Rating
Awg. Size#
Strands
Final
O.D.
(in)
Final
O.D.
(mm)
Wgt.
(lbs/Mft)
Wgt.
(kg/km)
Min. Bend
Radius
(in)
ULCSA
NNA22P007200C300V22 NPC 2%70.0711.803.924.140.573919AWM I A/B FT2
NNA20P007200C300V20 NPC 2%70.0781.985.445.370.623919AWM I A/B FT2
NNA18T007200C300V1870.0872.217.4411.070.703919AWM I A/B FT2
NNA16T007200C300V1670.0992.5110.7916.060.793919AWM I A/B FT2

VW-1 DuraBlend® 200C/600V

Part No.Temp
Rating
Voltage
Rating
Awg. Size#
Strands
Final
O.D.
(in)
Final
O.D.
(mm)
Wgt.
(lbs/Mft)
Wgt.
(kg/km)
Min. Bend
Radius
(in)
ULCSA
NPA22P007200C600V22 NPC 2%70.0802.034.747.050.643772AWM I A/B FT2
NPA20P007200C600V20 NPC 2%70.0872.216.038.970.703772AWM I A/B FT1
NPA18T007200C600V1870.0952.418.2412.260.763772AWM I A/B FT1
NPA16T007200C600V1670.1082.7411.6117.280.863772AWM I A/B FT1
NPA14T007200C600V1470.1203.0515.9923.800.963772AWM I A/B FT1
NPA14P041200C600V14 NPC 2%410.1203.0516.7324.900.963772AWM I A/B FT1
NPA12T019200C600V12190.1373.4824.9537.131.103772AWM I A/B FT1
NPA12P065200C600V12 NPC 2%650.1373.4825.2637.591.103772AWM I A/B FT1
NPA10T019200C600V10190.1654.1938.4457.211.323772AWM I A/B FT1

VW-1 DuraBlend® 200C/600V/1000V

Part No.Temp
Rating
Voltage
Rating
Awg. Size#
Strands
Final
O.D.
(in)
Final
O.D.
(mm)
Wgt.
(lbs/Mft)
Wgt.
(kg/km)
Min.
Bend Radius
(in)
ULCSA
NQA18P019200C600V/1000V18 NPC 2%190.0972.468.2312.250.783772/3788AWM I A/B FT1
NQA18T007200C600V/1000V1870.0972.468.2612.290.783772/3788AWM I A/B FT1
NQA16T007200C600V/1000V1670.1142.9012.2518.230.913772/3788AWM I A/B FT1
NQA14T007200C600V/1000V1470.1203.0516.0223.840.963772/3788AWM I A/B FT1
NQA12T019200C600V/1000V12190.1373.4824.9837.181.103772/3788AWM I A/B FT1
NQA10T019200C600V/1000V10190.1704.3239.0258.071.363772/3788AWM I A/B FT1
NQA08T061200C600V/1000V8610.2125.3863.9195.111.703772/3788AWM I A/B FT1
NQA06T084200C600V/1000V6840.3137.95105.81157.472.503772/3788AWM I A/B FT1
NQA04T133200C600V/1000V41330.3478.81146.37217.832.783772/3788AWM I A/B FT1
NQA02T259200C600V/1000V22590.41210.46223.69332.903.303772/3788AWM I A/B FT1
NQA01T259200C600V/1000V12590.44911.40275.44409.923.593772/3788AWM I A/B FT1
NQAX1T259200C600V/1000V1/02590.54413.82371.32552.614.353772/3788AWM I A/B FT1
NQAX2T259200C600V/1000V2/02590.58514.86458.49682.344.683772/3788AWM I A/B FT1
NQAX3T259200C600V/1000V3/02590.63916.23567.04843.895.113772/3788AWM I A/B FT1
NQAX4T259200C600V/1000V4/02590.69417.63704.561048.555.553772/3788AWM I A/B FT1

Standard conductor: Tinned Copper or Nickel Plated Copper (2%) as designated
Consult factory for alternative conductor and stranding options.

All dimensions listed above are nominal
Compliance: UL Listed File No. E22244. CSA Certfied File No. LL13427 or LL80670

WE HAVE THE SOLUTION.

At Radix, we do more than sell products; we provide solutions. We take the time to learn about each customer and your unique challenges, and then our knowledgeable team of problem solvers works to educate you on the possibilities to improve your products or operations. 

From cutting-edge technology applications to extreme industrial environments, we’re here to collaborate, innovate, and elevate your success. Let's connect.

OUR HIGH PERFORMANCE CABLE AND WIRE KNOWLEDGE IS YOURS, TRUST RADIX.