HI VOLT 1911

UL 1911 High Volt

HIGH-VOLTAGE LEAD WIRE

Ratings/Approvals:

  • 250°C – 10 KVDC – UL Style 1911
  • 250°C – 25 KVDC – UL Style 1911
  • 250°C – 30 KVDC – UL Style 1911
  • VW-1 Rated
  • RoHS Compliant

Construction:

  • Conductors
    • 24 AWG – 10 AWG
    • Stranded nickel-plated copper – 2%
      (Other conductor materials available)
  • Insulating System
    • Extruded perfluoroalkoxy copolymer (PFA)
  • Standard Color Coding
    • Available in Colors

Characteristics:

  • Offers smallest outside diameter of 250°C hi volt wires for ease in installation and lower assembly costs.
  • Mechanical toughness and low coefficient of friction allows “pull” installation of long lengths
  • Outstanding chemical and fluid resistance
  • Heat aging and ozone resistant
  • Easily stripped and terminated

SPECIFICATIONS

UL 1911 High Volt

HIGH-VOLTAGE LEAD WIRE

Download UL 1911 High Volt Specs

UL 1911 High Volt 250C/10KVDC

Part No.Temp RatingVoltage RatingAwg. Size# StrandsFinal O.D. (in)Final O.D. (mm)Wgt. (lbs/Mft)Wgt. (kg/km)Min. Bend Radius (in)UL
GOA24P007250C10000VDC2470.0621.563.815.670.491911
GOA22P007250C10000VDC2270.0681.735.037.490.551911
GOA20P007250C10000VDC2070.0751.906.429.560.601911
GOA18P019250C10000VDC18190.0822.088.4912.630.651911
GOA16P019250C10000VDC16190.0942.3812.2418.220.751911
GOA16P026250C10000VDC16260.0952.4012.3718.400.761911
GOA14P041250C10000VDC14410.1102.7817.8926.630.881911
GOA12P065250C10000VDC12650.1283.2626.8739.991.031911
GOA10P105250C10000VDC101050.1533.8940.7860.691.221911

UL 1911 High Volt 250C/25KVDC

Part No.Temp RatingVoltage RatingAwg. Size# StrandsFinal O.D. (in)Final O.D. (mm)Wgt. (lbs/Mft)Wgt. (kg/km)Min. Bend Radius (in)UL
GEA24P007250C25000VDC2470.0781.975.498.170.621911
GEA22P007250C25000VDC2270.0741.885.678.440.591911
GEA20P007250C25000VDC2070.0912.308.4212.530.731911
GEA18P019250C25000VDC18190.0982.4810.6615.860.781911
GEA16P019250C25000VDC16190.1102.7914.6921.870.881911
GEA16P026250C25000VDC16260.1112.8114.8422.090.881911
GEA14P041250C25000VDC14410.1263.1920.7330.851.001911
GEA12P065250C25000VDC12650.1443.6730.1644.891.161911
GEA10P105250C25000VDC101050.1694.2944.6666.471.351911

UL 1911 High Volt 250C/30KVDC

Part No.Temp RatingVoltage RatingAwg. Size# StrandsFinal O.D. (in)Final O.D. (mm)Wgt. (lbs/Mft)Wgt. (kg/km)Min. Bend Radius (in)UL
GLA24P007250C30000VDC2470.0862.176.489.640.681911
GLA22P007250C30000VDC2270.0922.347.9311.810.741911
GLA20P007250C30000VDC2070.0992.519.5614.230.791911
GLA18P019250C30000VDC18190.1062.6911.8817.690.851911
GLA16P019250C30000VDC16190.1182.9916.0723.910.941911
GLA16P026250C30000VDC16260.1193.0116.2224.140.951911
GLA14P041250C30000VDC14410.1343.3922.2933.181.071911
GLA12P065250C30000VDC12650.1523.8731.9547.551.221911
GLA10P105250C30000VDC101050.1774.5046.7569.581.421911

Standard conductor: Nickel Plated Copper (2%)
Consult factory for alternative conductor and stranding options.

All dimensions listed above are nominal
Compliance: UL Listed File No. E22244. CSA Certfied File No. LL13427 or LL80670