Radix Wire & Cable Contact Us
Product
HI VOLT 1911

UL 1911 PFA High Volt 250

HIGH-VOLTAGE LEAD WIRE

Ratings/Approvals:

250°C - 10 KVDC - UL Style 1911
250°C - 25 KVDC - UL Style 1911
250°C - 30 KVDC - UL Style 1911
VW-1 Rated
RoHS Compliant

Construction:

Conductors
24 AWG - 10 AWG
Stranded nickel-plated copper - 2%
(Other conductor materials available)

Insulating System

Extruded perfluoroalkoxy copolymer (PFA)

Standard Color Coding

Available in Colors

Characteristics:

  • Offers smallest outside diameter of 250°C hi volt wires for ease in installation and lower assembly costs.
  • Mechanical toughness and low coefficient of friction allows "pull" installation of long lengths
  • Outstanding chemical and fluid resistance
  • Heat aging and ozone resistant
  • Easily stripped and terminated

Specifications

UL 1911 PFA High Volt 250

HIGH-VOLTAGE LEAD WIRE
UL 1911 PFA High Volt 250
UL 1911 HIGH VOLTAGE 250C/10KVDC
Part No. Temp Rating Voltage Rating Awg. Size # Strands Final O.D. (in) Final O.D. (mm) Wgt. (lbs/Mft) Wgt. (kg/km) Min. Bend Radius (in) UL
GOA24P007 250C 10000VDC 24 7 0.062 1.56 3.81 5.67 0.49 1911
GOA22P007 250C 10000VDC 22 7 0.068 1.73 5.03 7.49 0.55 1911
GOA20P007 250C 10000VDC 20 7 0.075 1.90 6.42 9.56 0.60 1911
GOA18P019 250C 10000VDC 18 19 0.082 2.08 8.49 12.63 0.65 1911
GOA16P019 250C 10000VDC 16 19 0.094 2.38 12.24 18.22 0.75 1911
GOA16P026 250C 10000VDC 16 26 0.095 2.40 12.37 18.40 0.76 1911
GOA14P041 250C 10000VDC 14 41 0.110 2.78 17.89 26.63 0.88 1911
GOA12P065 250C 10000VDC 12 65 0.128 3.26 26.87 39.99 1.03 1911
GOA10P105 250C 10000VDC 10 105 0.153 3.89 40.78 60.69 1.22 1911
UL 1911 HIGH VOLTAGE 250C/25KVDC
Part No. Temp Rating Voltage Rating Awg. Size # Strands Final O.D. (in) Final O.D. (mm) Wgt. (lbs/Mft) Wgt. (kg/km) Min. Bend Radius (in) UL
GEA24P007 250C 25000VDC 24 7 0.078 1.97 5.49 8.17 0.62 1911
GEA22P007 250C 25000VDC 22 7 0.074 1.88 5.67 8.44 0.59 1911
GEA20P007 250C 25000VDC 20 7 0.091 2.30 8.42 12.53 0.73 1911
GEA18P019 250C 25000VDC 18 19 0.098 2.48 10.66 15.86 0.78 1911
GEA16P019 250C 25000VDC 16 19 0.110 2.79 14.69 21.87 0.88 1911
GEA16P026 250C 25000VDC 16 26 0.111 2.81 14.84 22.09 0.88 1911
GEA14P041 250C 25000VDC 14 41 0.126 3.19 20.73 30.85 1.00 1911
GEA12P065 250C 25000VDC 12 65 0.144 3.67 30.16 44.89 1.16 1911
GEA10P105 250C 25000VDC 10 105 0.169 4.29 44.66 66.47 1.35 1911
UL 1911 HIGH VOLTAGE 250C/30KVDC
Part No. Temp Rating Voltage Rating Awg. Size # Strands Final O.D. (in) Final O.D. (mm) Wgt. (lbs/Mft) Wgt. (kg/km) Min. Bend Radius (in) UL
GLA24P007 250C 30000VDC 24 7 0.086 2.17 6.48 9.64 0.68 1911
GLA22P007 250C 30000VDC 22 7 0.092 2.34 7.93 11.81 0.74 1911
GLA20P007 250C 30000VDC 20 7 0.099 2.51 9.56 14.23 0.79 1911
GLA18P019 250C 30000VDC 18 19 0.106 2.69 11.88 17.69 0.85 1911
GLA16P019 250C 30000VDC 16 19 0.118 2.99 16.07 23.91 0.94 1911
GLA16P026 250C 30000VDC 16 26 0.119 3.01 16.22 24.14 0.95 1911
GLA14P041 250C 30000VDC 14 41 0.134 3.39 22.29 33.18 1.07 1911
GLA12P065 250C 30000VDC 12 65 0.152 3.87 31.95 47.55 1.22 1911
GLA10P105 250C 30000VDC 10 105 0.177 4.50 46.75 69.58 1.42 1911

Standard conductor: Nickel Plated Copper (2%)
Consult factory for alternative conductor and stranding options.

All dimensions listed above are nominal
Compliance: UL Listed File No. E22244. CSA Certfied File No. LL13427 or LL80670

WE HAVE THE SOLUTION.

Radix’s team of technicians, engineers and researchers is committed to being innovators in the arena of high temperature wire and high temperature cable. Collectively we are on the tireless quest to provide the thinnest possible cable and wire while maintaining the highest possible performance.

We can help you find the wire and cable solution best suited for your application – just get in touch.

Our High Performance Cable And Wire Knowledge Is Yours, Trust Radix.