Radix Wire & Cable Contact Us
Product
DuraFlex® 450

DuraFlex® 450

HIGH-TEMPERATURE WIRE

Ratings/Approvals:

  • 450°C - 300 Volts - UL 5334 / 5128 / CSA AWM I A/B FT1
  • 450°C - 600 Volts - UL 5335 / 5107 / CSA AWM I A/B FT1
  • VW-1 Flame Rated

Construction:

  • Conductors
    • 24 AWG - 14 AWG (300 Volts)
    • 22 AWG - 8 AWG (600 Volts)
    • Stranded nickel-coated copper - 27%
      (Other conductor materials available)
  • Insulating System
    • Mica glass composite
  • Outer Covering
    • Fiberglass braid with high temperature finish
  • Standard Color Coding
    • Natural and Solid Colors
    • Colored Tracers

Characteristics:

  • Outperforms UL 5128/5107 MGT products:
    • Unique insulation system offers outstanding heat-aged flexibility for longer service life.
    • Passes UL 2X mandrel test after heat aging (UL 5128/5107 is 3X mandrel).
    • Excellent cutting and stripping characteristics, making it ideal for high volume manufacturing and assembly.
    • Provides dimensional consistency and uniformity.
  • Resists braid pushback.
  • Withstands mechanical abuse.

Specifications

DuraFlex® 450

HIGH-TEMPERATURE WIRE
DuraFlex<sup>®</sup> 450
DuraFlex 450C/300V
Part No. Awg. Size # Strands Outer Dia. inches Outer Dia. mm Wgt. (lbs/Mft) Wgt (kg/km) Min. Bend Radius (in) UL CSA
DGT24C007 24 7 0.068 1.73 4 6.37 0.54 5334/5128 AWM I A/B FT1
DGT22C007 22 7 0.081 2.06 6 8.83 0.65 5334/5128 AWM I A/B FT1
DGT20C010 20 10 0.088 2.24 8 11.19 0.70 5334/5128 AWM I A/B FT1
DGT18C016 18 16 0.096 2.44 10 14.51 0.77 5334/5128 AWM I A/B FT1
DGT16C026 16 26 0.110 2.79 14 20.43 0.88 5334/5128 AWM I A/B FT1
DGT14C041 14 41 0.126 3.20 20 29.33 1.01 5334/5128 AWM I A/B FT1
DuraFlex 450C/600V
Part No. Awg. Size # Strands Outer Dia. inches Outer Dia. mm Wgt. (lbs/Mft) Wgt (kg/km) Min. Bend Radius (in) UL CSA
DHT22C007 22 7 0.098 2.49 7 11.01 0.78 5335/5107 AWM I A/B FT1
DHT20C010 20 10 0.108 2.74 10 14.53 0.86 5335/5107 AWM I A/B FT1
DHT18C016 18 16 0.120 3.05 13 19.05 0.96 5335/5107 AWM I A/B FT1
DHT16C026 16 26 0.134 3.40 17 25.54 1.07 5335/5107 AWM I A/B FT1
DHT14C041 14 41 0.150 3.81 23 34.62 1.20 5335/5107 AWM I A/B FT1
DHT12C065 12 65 0.170 4.32 33 49.22 1.36 5335/5107 AWM I A/B FT1
DHT10C105 10 105 0.211 5.36 52 77.25 1.69 5335/5107 AWM I A/B FT1
DHT08C133 8 133 0.261 6.63 77 114.21 2.09 5335/5107 AWM I A/B FT1

Standard conductor: Nickel Coated Copper - 27%
Consult factory for alternative conductor and stranding options.

WE HAVE THE SOLUTION.

Radix’s team of technicians, engineers and researchers is committed to being innovators in the arena of high temperature wire and high temperature cable. Collectively we are on the tireless quest to provide the thinnest possible cable and wire while maintaining the highest possible performance.

We can help you find the wire and cable solution best suited for your application – just get in touch.

Our High Performance Cable And Wire Knowledge Is Yours, Trust Radix.