UL SILICONE JACKETED

UL Silicone Jacketed

HIGH-TEMPERATURE CABLES

Ratings/Approvals:

  • SILICONE JACKETED CABLE:
    • 150°C / 200°C – 600 Volts – UL Style 4389 / CSA AWM I A/B FT2
  • HI-LITE CABLE:
    • 150°C – 300 Volts – UL Style 3522
    • 200°C – 300 Volts – UL Style 4291 / CSA AWM I/II A/B FT2
  • PENDANT CABLE:
    • 150°C – 300 Volts – UL Style 4403
    • 200°C – 600 Volts – UL Style 4452

Construction:

  • SILICONE JACKETED CABLE:
    • Stranded tinned copper (2 to 61 conductors) with braided silicone rubber insulation (braidless silicone rubber or Teflon® also available UL only) and extruded silicone rubber jacket.
  • HI-LITE CABLE:
    • Stranded tinned copper (2 conductors 16 or 18 AWG) with braided silicone rubber insulation and extruded silicone rubber jacket. Options for UL 4291:
    • Twisted Kevlar, Aramid or polyester strength member laid parallel
    • Insulated or uninsulated ground lead
  • PENDANT CABLE:
    • Stranded tinned copper (2 conductors 16 or 18 AWG) with braided silicone rubber insulation and extruded silicone rubber jacket. Twisted Kevlar, Aramid or polyester strength member required. Optional Insulated or uninsulated ground lead.

Characteristics:

  • Silicone formulations suitable for UV, ozone, moisture exposure
  • Not suited for immersed applications
  • Suitable for applications to -60°C
  • Silicone Rubber in extreme environments, exceeding 200°C, leaves a non-conductive ash and retains excellent insulation properties
  • Flexible

SPECIFICATIONS

UL Silicone Jacketed

HIGH-TEMPERATURE CABLES

Download UL Silicone Jacketed Specs

SILICONE JACKETED CABLE 200C/600V

Part No.Awg. Size# StrandsOuter Dia. inchesOuter Dia. mmWgt (lbs/Mft)Wgt (kg/km)Min Bend Radius (in)ULCSA 180C
KK14AT03A-0000-A5K20 (1)1470.3849.7596142.453.074389AWM I A/B FT2
KK16AT03A-0000-A5K20 (1)1670.3569.0477114.152.854389AWM I A/B FT2
KK18AT03A-0000-A5K20 (1)1870.3288.336393.942.624389AWM I A/B FT2
KJ14AT03A-0000-A5K20 (2)1470.48612.34106134.933.894389AWM I A/B FT2
KJ16AT03A-0000-A5K20 (2)1670.3899.8888130.913.114389AWM I A/B FT2
KJ18AT03A-0000-A5K20 (2)1870.3639.2274109.522.904389AWM I A/B FT2
KK14AT03A-CL01-A5K20 (3)1470.3188.0879117.212.544389AWM I A/B FT2
KK16AT03A-CL01-A5K20 (3)1670.2857.245987.182.284389AWM I A/B FT2
KK18AT03A-CL01-A5K20 (3)1870.2586.554668.072.064389AWM I A/B FT2

HI-LITE CABLE 150C/300V

Part No.Awg. Size# StrandsOuter Dia. inchesOuter Dia. mmWgt (lbs/Mft)Wgt (kg/km)Min Bend Radius (in)ULCSA 180C
CMB18B168181680.2686.813754.902.143522N/A
CNB18B168181680.164 x 0.2664.17 x 6.764643.972.133522N/A

HI-LITE CABLE 200C/300V

Part No.Awg. Size# StrandsOuter Dia. inchesOuter Dia. mmWgt (lbs/Mft)Wgt (kg/km)Min Bend Radius (in)ULCSA 180C
CPB18T0071870.158 x 0.2544.01 x 6.452843.012.034291AWM I/II A/B FT2

PENDANT CABLE 150C/300

Part No.Awg. Size# StrandsOuter Dia. inchesOuter Dia. mmWgt (lbs/Mft)Wgt (kg/km)Min Bend Radius (in)ULCSA 180C
CSB18B168181680.2686.813755.912.144403N/A

Standard conductor: Bare Copper (150C) and Tinned Copper (200C)
Consult factory for alternative conductor and stranding options.