Radix Wire & Cable Contact Us
Product
DuraLife® II Dual Rated CIC/CI

DuraLife® Dual Rated Multi-conductor FPLR

Shielded/Unshielded Fire Resistive Cables

Applications:

  • Hospitals & Healthcare Facilities.
  • High Rise & Mix use buildings.
  • Universities & College Campuses.
  • Stadiums, Casinos, places of assembly.
  • Government Facilities .

COMPLIANCE:

  • UL 1424 Listed FPLR/FPLR-CI (dual-rated) for Power-Limited Fire Alarm Circuits. Riser Rated. 300V/105°C classified.
  • UL Certified to UL 2196 2-hour fire rating in FHIT 28D
  • UL Certified 2-hour fire rating as FPLR-CI for Free Air installed per NEC code
  • Fire alarm circuit integrity, emergency systems, and healthcare facilities (NEC Articles 760, 700 & 517)
  • Meets National Fire Protection Code (NFPA 70 & 72) fire alarm survivability circuit requirements
  • Compliance tested to UL 1424 as suitable for use in applications requiring wet rating
  • Tested for Sunlight Resistance in compliance with UL 2556 requirements
  • Suitable for 2-hour certified fire-resistive applications in EMT or IMC conduit systems
  • UL Listed File No. E-241484. UL Fire Directory R-21213.
  • Splice Allowance

Construction:

  • Conductor: Oxygen-free bare copper (OFHC), solid and/or stranded
  • Insulation: Proprietary ceramifiable silicone rubber
  • Assembly: Numerically printed black/red paired leads
  • Jacket: Red low smoke/zero halogen FRPE (black jacket available/special order)

HARDWARE CERTIFIED: (Refer to DuraLife® II Multi-Conductor Installation Guide for additional details)

  • EMT/IMC Conduit: Wheatland/Western Tube
  • EMT/IMC Conduit: Allied/Columbia (EMT: E-Z Pull Brand)
  • EMT Compression Couplings: Hubbell-Raco or Halex
  • NEMA 1 Splice Enclosure/Pull Box: Eaton/Cooper
  • Pulling Lubricant: Polywater LZ
  • Box Fitting Connectors:
    • Compression – Cooper Crouse-Hinds (EMT);Hubbell-Raco (EMT/IMC)
    • Set Screw - Hubbell-Raco (EMT/IMC)
  • Splice Connector: 3M Butt-Type Crimp Terminals
  • Splice Tapes – 1”: 3M Silicone; St. Gobain Fiberglass Tape

Specifications

DuraLife® Dual Rated Multi-conductor FPLR

Shielded/Unshielded Fire Resistive Cables
DuraLife<sup>®</sup> Dual Rated Multi-conductor FPLR

NON-SHIELDED: RADIX WIRE-II DURALIFE-IITM E241484 #/C #AWG FPLR/FPLR-CI / 300V/105C / (UL) 2196 2-HR FIRE RESISTIVE CABLE
FOR USE IN FHIT ELECTRIC CIRCUIT INTEGRITY SYSTEM #28D. SEE UL FIRE RESISTANCE DIRECTORY R21213 // Sun Res Wet
(MONTH/YEAR) (XXXX FT)

RADIX P/N AWG/ COND. SOLID OR STRANDED NOMINAL O.D. (INCH) COND. RESISTANCE (OHMs/FT) NOM.CAP. (pF/FT) (per pair) EMT/IMC UNSHIELDED MAX CABLE FILL ALLOWANCE (for in-conduit installations per FHIT 28D)
¾” 1” 1 ¼” 1 ½" 2”
CTU18A0104 18/4C Solid 0.366 6.48 14.4 1 2 4 6 10
CTU18A0106 18/6C Solid 0.444 6.48 14.4 1 1 3 4 7
CTU18A0108 18/8C Solid 0.518 6.48 14.4 X 1 2 3 5
CTU16A0104 16/4C Solid 0.405 3.99 15.3 1 2 3 4 8
CTU16A0106 16/6C Solid 0.485 3.99 15.3 X 1 2 3 5
CTU16A0108 16/8C Solid 0.575 3.99 15.3 X 1 1 2 4
CTU14A0104 14/4C Solid 0.431 2.57 17.1 1 1 3 4 7
CTU14A0106 14/6C Solid 0.523 2.57 17.1 X 1 2 3 5
CTU14A0108 14/8C Solid 0.629 2.57 17.1 X X 1 2 3
CTU12A0704 12/4C 7-Strand 0.483 1.64 17.6 X 1 2 3 5
CTU12A0706 12/6C 7-Strand 0.633 1.64 17.6 X X 1 2 3
CTU12A0708 12/8C 7-Strand 0.708 1.64 17.6 X X 1 1 2

SHIELDED: RADIX WIRE-II DURALIFE-IITM E241484 #/C #AWG FPLR/FPLR-CI / SHLD./ 300V/105C / (UL) 2196 2-HR FIRE RESISTIVE CABLE FOR USE IN FHIT ELECTRIC CIRCUIT INTEGRITY SYSTEM #28D. SEE UL FIRE RESISTANCE DIRECTORY R21213 // Sun Res Wet (MONTH/YEAR) (XXXX FT)

RADIX P/N #COND SOLID OR STRANDED NOMINAL O.D. (INCH) COND. RESISTANCE (OHMs/FT) NOM. CAP. (pF/FT) (per pair) EMT/IMC SHIELDED MAX CABLE FILL ALLOWANCE (for in-conduit installations per FHIT 28D)
¾” 1” 1 ¼” 1 ½" 2”
CTS18A0104 18/4C Solid 0.389 6.48 18.4 1 2 4 5 5
CTS18A0106 18/6C Solid 0.472 6.48 18.4 1 1 2 3 3
CTS18A0108 18/8C Solid 0.551 6.48 18.4 X 1 1 2 2
CTS16A0104 16/4C Solid 0.411 3.99 19.1 1 2 3 5 8
CTS16A0106 16/6C Solid 0.492 3.99 19.1 X 1 2 3 5
CTS16A0108 16/8C Solid 0.583 3.99 19.1 X 1 1 2 4
CTS14A0104 14/4C Solid 0.463 2.57 21.4 1 1 2 4 6
CTS14A0106 14/6C Solid 0.562 2.57 21.4 X 1 1 2 4
CTS14A0108 14/8C Solid 0.676 2.57 21.4 X X 1 1 3

WE HAVE THE SOLUTION.

Radix’s team of technicians, engineers and researchers is committed to being innovators in the arena of high temperature wire and high temperature cable. Collectively we are on the tireless quest to provide the thinnest possible cable and wire while maintaining the highest possible performance.

We can help you find the wire and cable solution best suited for your application – just get in touch.

Our High Performance Cable And Wire Knowledge Is Yours, Trust Radix.