DuraLife II Dual Rated Ethernet FPLR

DuraLife® Ethernet Dual-Rated CIC/CI Cables

Multi-Conductor FPLR Shielded/Unshielded Fire Resistive Cables

Certified to the harsh requirements of the UL2196 Test for Fire Resistive Cables, the DuraLife II Dual Rated CIC /CI cables ensure two-hour operation of critical systems in the event of a fire. The dual rating design offers the most versatility in meeting code survivability requirements in both in-conduit and free air installation scenarios.

Description: Dual Rated Multi-Conductor CI/CIC Cable. UL 2196 Certified/UL 1424 Listed. FHIT System No. 28D. Low smoke, zero halogen design (LSZH). FHIT7 System No. 28D (CSA Listed)

Sizes Available: 18 AWG unshielded;18 AWG shielded. 2/PR through 4/PR constructions

Construction:

  • Conductor: Oxygen-free bare copper (OFHC), solid and/or stranded
  • Insulation: Proprietary ceramifiable silicone rubber
  • Assembly: Numerically printed black/red paired leads
  • Jacket: Red low smoke/zero halogen FRPE with sequential footage markers (custom colors available/special order mins apply)

Applications:

  • Hospitals & Healthcare Facilities
  • High Rise & Mix use buildings
  • Universities & College Campuses
  • Stadiums, Casinos, places of assembly
  • Government Facilities

Critical Systems:

  • Area of Refuge Systems
  • Emergency VoIP communication
  • Addressable Class N Fire Alarm systems
  • BMS and Low Voltage Emergency Lighting

Compliance:

  • UL 1424 Listed FPLR/FPLR-CI (dual-rated) for Power-Limited Fire Alarm Circuits. Riser Rated. 300V/105°C classified.
  • UL / CAN (ULC formerly S-139) Certified to UL 2196 2 hour fire rating in FHIT/FHIT7 28D
  • CSA Certified to CSA Std. C22.2 No. 208; Type FAS90, 300V/90C FT4-ST1
  • UL Certified 2-hour fire rating as FPLR-CI for Free Air installed per NEC code
  • Fire alarm circuit integrity, emergency systems, and healthcare facilities (NEC Articles 760, 700 & 517)
  • Meets National Fire Protection Code (NFPA 70 & 72) fire alarm survivability circuit requirements
  • Meets National Fire Protection Code (NFPA 130 & 502) fire alarm survivability circuit requirements
  • Meets UL1685 and FT4/IEEE 1202 requirements
  • Compliance tested to UL 1424 as suitable for use in applications requiring wet rating
  • Tested for Sunlight Resistance in compliance with UL 2556 requirements
  • Suitable for 2-hour certified fire-resistive applications in EMT or IMC conduit systems
  • UL Listed File No. E-241484. UL Fire Directory R-21213.
  • CAFM approved
  • Meets Category 3 requirements per TIA-568-C.2 throughout UL2196 Flame and Hose Stream Testing

Hardware Certified: (Refer to DuraLife®II Multi-Conductor Installation Guide for additional details)

  • EMT/IMC Conduit: Wheatland/Western Tube
  • EMT/IMC Conduit: Allied/Columbia (EMT: E-Z Pull Brand)
  • EMT Compression Couplings: Hubbell-Raco or Halex
  • NEMA 1 Splice Enclosure/Pull Box: Eaton/Cooper
  • Pulling Lubricant: Polywater LZ
  • Box Fitting Connectors:
    • Compression – Cooper Crouse-Hinds (EMT);Hubbell-Raco (EMT/IMC)
    • Set Screw – Hubbell-Raco (EMT/IMC)
  • Splice Connector: 3M Butt-Type Crimp Terminals
  • Splice Tapes – 1”: 3M Silicone; St. Gobain Fiberglass Tape

SPECIFICATIONS

DuraLife® Ethernet Dual-Rated CIC/CI Cables

Multi-Conductor FPLR Shielded/Unshielded Fire Resistive Cables

Download DuraLife® Ethernet Dual-Rated CIC/CI Cable Specs

UNSHIELDED

RADIX WIRE-II DURALIFE-II™ E241484 #/P #AWG FPLR/FPLR-CI / 300V/105C / (UL) 2196 (ULC) 2-HR FIRE RESISTIVE CABLE FOR USE IN FHIT/FHIT7 ELECTRIC CIRCUIT INTEGRITY SYSTEM #28D. SEE UL FIRE RESISTANCE DIRECTORY R21213 // CSA LL80670 FAS90 90C/300V FT4-ST1// SUN RES/WET (MONTH/YEAR)

RADIX P/NAWG/
COND.*
SOLIDNOMINAL
O.D.
(INCH)
COND. RESISTANCE
(OHMs/MFT)
NOM.CAP.
(pF/FT) (per pair)
EMT/IMC UNSHIELDED MAX CABLE FILL ALLOWANCE
(for in-conduit installations per FHIT 28D)
¾”1”1 ¼”1 ½”2”
CTU18A0104-CAT318/2PSolid0.3666.4814.4124610
CTU18A0106-CAT318/3PSolid0.4446.4814.411347
CTU18A0108-CAT318/4PSolid0.5186.4814.4X1235

* Numerically printed black /red paired leads

SHIELDED

RADIX WIRE-II DURALIFE-II™ E241484 #/P #AWG FPLR/FPLR-CI / SHLD./ 300V/105C / (UL) 2196 (ULC) 2-HR FIRE RESISTIVE CABLE FOR USE IN FHIT/FHIT7 ELECTRIC CIRCUIT INTEGRITY SYSTEM #28D. SEE UL FIRE RESISTANCE DIRECTORY R21213 // CSA LL80670 FAS90 90C/300V FT4-ST1// SUN RES/WET (MONTH/YEAR)

RADIX P/NAWG/
COND.*
SOLIDNOMINAL
O.D.
(INCH)
COND. RESISTANCE
(OHMs/MFT)
NOM. CAP.
(pF/FT) (per pair)
EMT/IMC SHIELDED MAX CABLE FILL ALLOWANCE
(for in-conduit installations per FHIT 28D)
¾”1”1 ¼”1 ½”2”
CTS18A0104-CAT318/2PSolid0.3896.4818.412455
CTS18A0106-CAT318/3PSolid0.4726.4818.411233
CTS18A0108-CAT318/4PSolid0.5516.4818.4X1122

* Numerically printed black /red paired leads

WE HAVE THE SOLUTION.

At Radix, we do more than sell products; we provide solutions. We take the time to learn about each customer and your unique challenges, and then our knowledgeable team of problem solvers works to educate you on the possibilities to improve your products or operations. 

From cutting-edge technology applications to extreme industrial environments, we’re here to collaborate, innovate, and elevate your success. Let's connect.

OUR HIGH PERFORMANCE CABLE AND WIRE KNOWLEDGE IS YOURS, TRUST RADIX.