DuraLife® Dual-Rated CIC/CI Cables

UL 2196 2-Hour Fire Resistive Cable FPLR Shielded / Unshielded 105°C/300V

Certified to the harsh requirements of the UL2196 Test for Fire Resistive Cables, the
DuraLife Dual-Rated CIC/CI cables ensure two-hour operation of critical systems in
the event of a fire. The dual rating design offers the most versatility in meeting code
survivability requirements in both in-conduit and free air installation scenarios.

Description: Dual-Rated CIC/CI Cable. UL/CAN (ULC) 2196 Certified/UL 1424 Listed. FHIT/
FHIT7 (ULC) System No. 28C. Low smoke, zero halogen design (LSZH).

Sizes Available: 2 conductor, 18-12 AWG unshielded; 18-14 AWG shielded.

Construction:

  • Conductor: Oxygen-free bare copper (OFHC), solid and/or stranded
  • Insulation: Proprietary ceramifiable silicone rubber
  • Assembly: Color-coded black/red leads, 3 twists/foot
  • Jacket: Red low smoke/zero halogen FRPE with sequential footage markers (custom colors available/special order mins apply)

Applications:

  • Hospitals & Healthcare Facilities
  • High Rise & Mix Use Buildings
  • Universities & College Campuses
  • Stadiums, Casinos, Places of Assembly
  • Transit Bridges, Tunnels and Subways
  • Government Facilities

Critical Systems:

  • Fire Alarm and EVAC Systems
  • Smoke Evacuation and Control
  • Fan & Pressurization Systems
  • Strobes & Notification Appliances
  • Area of Refuge Systems
  • Emergency Lighting

COMPLIANCE:

  • UL 1424 Listed FPLR/FPLR-CI (dual-rated) for Power-Limited Fire Alarm Circuits. Riser Rated. 300V/105°C classified
  • UL / CAN (ULC formerly S-139) Certified to UL 2196 2-hour fire rating in FHIT / FHIT7 28C
  • CSA Certified FAS90; CSA Std. C22.2 No. 208-14 FT4-ST1
  • UL Certified 2-hour fire rating as FPLR-CI for Free Air installed per NEC code
  • UL 444 Listed “CMR/CMR-CI” as Communications Cable
  • Fire alarm circuit integrity, emergency systems, and healthcare facilities (NEC Articles 760, 700 & 517)
  • Meets National Fire Protection Code (NFPA 70 & 72) fire alarm survivability circuit requirements
  • Meets National Fire Protection Code (NFPA 130 & 502) fire alarm survivability circuit requirements
  • Compliance tested to UL 1424 as suitable for use in applications requiring wet rating
  • Meets UL1685 and FT4/IEEE 1202 requirements
  • Tested for Sunlight Resistance in compliance with UL 2556 requirements
  • Suitable for 2-hour certified fire-resistive applications in EMT, IMC, or Phenolic conduit systems
  • UL Listed File No. E-241484. UL Fire Directory R-21213
  • Splice Allowance
  • Performance testing of cables, cold bend test of complete cable per defined testing parameters and UL 1424
  • NYC certified and CAFM approved

HARDWARE & ACCESSORIES CERTIFIED: (Refer to DuraLife® II Installation Instructions/ Phenolic Addendum for details)

  • EMT/IMC Conduit: Wheatland/Western Tube
  • EMT/IMC Conduit: Allied/Columbia (EMT: E-Z Pull Brand)
  • Phenolic Conduit: Champion Fiberglass
  • EMT/IMC Compression Couplings: Hubbell/Raco
  • EMT/IMC Set-Screw Coupling: Hubbell/Raco
  • Phenolic Coupling: Champion Fiberglass
  • NEMA 1 Splice Enclosure/Pull Box: Eaton/Cooper (system use only)
  • Standard UL listed steel 4/S Utility Box (CI only)
  • Expansion Couplers: Bridgeport fittings (EMT/IMC)
  • Box Fittings: Compression – Cooper Crouse-Hinds (EMT); Hubbell/Raco (EMT/IMC) Set Screw – Hubbell/Raco (EMT/IMC) Phenolic – Champion Fiberglass
  • Conduit Clamps: Erico (Phenolic conduit only)
  • Splice Connector: 3M Butt-Type Crimp Terminals
  • Splice Tapes – 1”: 3M Silicone; St. Gobain Fiberglass Tape
  • Pulling Lubricant: Polywater LZ

SPECIFICATIONS

DuraLife® Dual-Rated CIC/CI Cables

UL 2196 2-Hour Fire Resistive Cable FPLR Shielded / Unshielded 105°C/300V

Download DuraLife® Dual Rated CIC/CI Cable Specs

UNSHIELDED

RADIX WIRE-II DURALIFE-IITM E241484 2/C #AWG FPLR/FPLR-CI/CMR 300V/105C / (UL) 2196 (ULC) 2-HR FIRE RESISTIVE CABLE FOR USE IN FHIT/FHIT7 ELECTRIC CIRCUIT INTEGRITY SYSTEM #28C. SEE UL FIRE RESISTANCE DIRECTORY R21213 // CSA LL13427 FAS90 300V FT4-ST1 Sun Res Wet (MONTH/YEAR) CI – NYC certified fire alarm cable (XXXX FT)

RADIX P/N#CONDAWGSOLID OR STRANDEDNOMINAL O.D. (INCH)NET WEIGHT (LBS PER MFT)RESISTANCE (OHMs/MFT)NOMINAL CAPACITANCE (pF/FT)
CTU18A0102218Solid0.305536.4814.4
CTU16A0102216Solid0.335623.9915.3
CTU16A0702216Stranded0.335624.0215.6
CTU14A0102214Solid0.344772.5717.1
CTU14A0702214Stranded0.350772.6017.3
CTU12A0102212Solid0.392981.6117.4
CTU12A0702212Stranded0.392981.6417.6

SHIELDED

RADIX WIRE-II DURALIFE-IITM E241484 2/C #AWG FPLR/FPLR-CI/CMR/SHLD 300V/105C / (UL) 2196 (ULC) 2-HR FIRE RESISTIVE CABLE FOR USE IN FHIT/FHIT7 ELECTRIC CIRCUIT INTEGRITY SYSTEM #28C. SEE UL FIRE RESISTANCE DIRECTORY R21213 // CSA LL13427 FAS90 300V FT4-ST1 Sun Res Wet (MONTH/YEAR) CI – NYC certified fire alarm cable (XXXX FT)

RADIX P/N#CONDAWGSOLID OR STRANDEDNOMINAL O.D. (INCH)NET WEIGHT (LBS PER MFT)RESISTANCE (OHMs/MFT)NOMINAL CAPACITANCE (pF/FT)
CTS18A0102218Solid0.335556.4818.4
CTS16A0102216Solid0.360653.9919.1
CTS16A0702216Stranded0.360654.0219.4
CTS14A0102214Solid0.390792.5721.4
CTS14A0702214Stranded0.393792.6021.7

System Fill Allowances (EMT – 1/2″ to 2″; IMC – 3/4″ to 2″)

EMT/IMC½”¾”1″1 ¼”1 ½”2″
Part No.No. of Cables Max Fill
CTU18A0102124610N/A
CTU16A01021135710
CTU14A01021135710
CTU12A01021124510V/9H
CTS18A010211358N/A
CTS16A01021135710
CTS14A0102N/A124610

System Fill Allowances (Phenolic Conduit – 1″ to 2″)

PHENOLIC1″1 ¼”1 ½”2″
Part No.No. of Cables Max Fill
CTU18A0102369N/A
CTU16A010224610
CTU14A010235710
CTU12A010224510V/9H
CTS18A0102357N/A
CTS16A010224610
CTS14A010224610

WE HAVE THE SOLUTION.

At Radix, we do more than sell products; we provide solutions. We take the time to learn about each customer and your unique challenges, and then our knowledgeable team of problem solvers works to educate you on the possibilities to improve your products or operations. 

From cutting-edge technology applications to extreme industrial environments, we’re here to collaborate, innovate, and elevate your success. Let's connect.

OUR HIGH PERFORMANCE CABLE AND WIRE KNOWLEDGE IS YOURS, TRUST RADIX.