TLC 200
HOT METAL TRANSFER CAR CABLE
600 VOLT 200 C, SPECIFICATION RW-20040
SIZES 18 AWG THROUGH 4/0

Part
Number


KR14GT04S
KR14GT07S
KR14GT12S
KR12GT02S
KR12GT03S
KR12GT04S
KR12GT06S
KR12GT08S
KR12GT10S
KR12GT12S
KR10GT02S
KR10GT03S
KR10GT04S
KR10GT08S
KR10GT12S
KR08ET02S
KR08ET03S
KR08ET04S
KR06ET02S
KR06ET03S
KR06ET04S
KR04ET03S
KR04ET04S
KR02ET03S
KR02ET04S
KRO1ET03S
KRO1ET04S
KRX1ET03S
KRX1ET04S
AWG
Size &
Stranding


14 (41)
14 (41)
14 (41)
12 (65)
12 (65)
12 (65)
12 (65)
12 (65)
12 (65)
12 (65)
10 (105)
10 (105)
10 (105)
10 (105)
10 (105)
8 (133)
8 (133)
8 (133)
6 (133)
6 (133)
6 (133)
4 (133)
4 (133)
2 (259)
2 (259)
1 (259)
1 (259)
1/0 (259)
1/0 (259)

Number of
Conductors


4
7
12
2
3
4
6
8
10
12
2
3
4
7
12
2
3
4
2
3
4
3
4
3
4
3
4
3
4
Insulated
Conductor
Diam. (In)


0.179
0.179
0.179
0.195
0.195
0.195
0.195
0.195
0.195
0.195
0.222
0.222
0.222
0.222
0.222
0.314
0.314
0.314
0.364
0.364
0.364
0.422
0.422
0.490
0.490
0.561
0.561
0.611
0.611
Insulation
Thickness
(In)


0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.045
0.060
0.060
0.060
0.060
0.060
0.060
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
Jacket
Thickness
(In)


0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
0.070
Nominal
Diameter
(In)


0.524
0.643
0.852
0.491
0.520
0.581
0.701
0.766
0.900
0.931
0.536
0.581
0.636
0.770
1.056
0.731
0.788
0.858
0.826
0.880
0.970
0.996
1.102
1.137
1.257
1.320
1.461
1.418
1.571
Approximate
Weight
(Lbs/Mft)


230.0
338.7
535.3
185.6
228.4
285.4
386.7
481.4
590.8
674.6
232.6
299.7
366.3
564.3
902.8
363.4
467.5
580.5
462.5
615.5
769.5
821.2
1046.7
1139.8
1461.5
1440.0
1862.6
1721.9
2222.6


Please Contact Our Factory for Sizes or Information Not Listed.

All material included in this bulletin is advisory only and its use by anyone is entirely voluntary. Information herein is believed to be accurate as of publication date, however, if errors exist they are unintentional and Radix is not responsible for any claim traceable to such an error. For applications that require tight tolerances, please contact the Radix factory for dimensional verification. Reliance upon the contents of this bulletin for any purpose by anyone is at the sole risk of that person and Radix Wire Co. Inc. is not responsible for any loss, claim or damage arising therefrom. Information contained in this bulletin is subject to change without notice. All users are cautioned that any UL and CSA approvals referenced in this publication may be revised or withdrawn at any time. Interested persons may receive current information concerning the status of any listing by contacting the appropriate listing body: UL or CSA.

Complete our
application questionnaire for a free quote.

Features | Construction | Specifications

©1999 Radix Wire Company
Problems? Contact our
webmaster.