TGGT
HIGH TEMPERATURE LEAD WIRE
600 VOLT 250 C, SPECIFICATION RW-25001
UL AND CSA APPROVED
Effective 11/98

   Part     Size   Strands/   Conductor   Insul.   Braid     Nominal    Approx.      UL
  Number    AWG/    Strand    Diameter    Thick.   Thick.    Diameter   Weight     Style
            MCM    Dia.(In)     (In)      (In)     (In)       (In)     (Lbs/Mft)

AHT24P007    24      7/0079     0.023      .027     .006       0.094      8.2      5127
AHT22P007    22     7/.0100     0.029      .027     .006       0.099      9.3      5127
AHT20P010    20    10/.0100     0.036      .027     .006       0.106     11.2      5127
AHT18P016    18    16/.0100     0.045      .027     .005       0.113     13.9      5127
AHT16P026    16     26/0100     0.056      .027     .005       0.124     18.2      5127
AHT14P041    14     41/0100     0.072      .027     .005       0.140     24.8      5127
AHT12P065    12     65/0100     0.088      .027     .005       0.156     34.1      5127
AHT10P105    10    105/0100     0.115      .027     .005       0.183     49.1      5127
AHE08P133     8    133/0111     0.164      .027     .005       0.232     74.9      5127
AHE06P133     6    133/0140     0.206      .038     .010       0.306    118.3      5196
AHE04P133     4    133/0177     0.262      .038     .010       0.362    174.2      5196
AHE02P133     2    133/0225     0.335      .038     .010       0.435    263.0      5196
AHE01P259     1    259/0177     0.378      .048     .015       0.503    351.1      5196
AHEX1P259   1/0    259/0202     0.415      .048     .015       0.540    450.1      5196
AHEX2P259   2/0    259/0227     0.465      .048     .015       0.590    555.3      5196
AHEX3P259   3/0    259/0255     0.533      .048     .015       0.658    646.4      5196
AHEX4P259   4/0    259/0286     0.601      .048     .015       0.726    797.2      5196
All Dimensions are Nominal.

Also Available in Multi-Pair Constructions.
Please Contact Our Factory for Sizes or Information Not Listed.
All material included in this bulletin is advisory only and its use by anyone is entirely voluntary. Information herein is believed to be accurate as of publication date, however, if errors exist they are unintentional and Radix is not responsible for any claim traceable to such an error. For applications that require tight tolerances, please contact the Radix factory for dimensional verification. Reliance upon the contents of this bulletin for any purpose by anyone is at the sole risk of that person and Radix Wire Co. Inc. is not responsible for any loss, claim or damage arising therefrom. Information contained in this bulletin is subject to change without notice. All users are cautioned that any UL and CSA approvals referenced in this publication may be revised or withdrawn at any time. Interested persons may receive current information concerning the status of any listing by contacting the appropriate listing body: UL or CSA.


Complete our application questionnaire for a free quote.