MGT
HIGH TEMPERATURE LEAD WIRE
600 VOLT 450 C, SPECIFICATION RW-45001
UL AND CSA APPROVED
Effective 11/98

   Part    Size   Strands/  Conductor  Insulation   Braid    Nominal   Approx.
  Number   AWG/    Strand   Diameter   Thickness  Thickness  Diameter  Weight
           MCM    Dia. (In)   (In)        (In)      (In)      (In)    (Lbs/Mft)

BET22C007   22      7/0100    0.029      0.028      0.007     0.101     7.0 
BET20C010   20     10/0100    0.036      0.028      0.007     0.106     8.5 
BET18C016   18     16/0100    0.045      0.028      0.007     0.117    11.5 
BET16C026   16     26/0100    0.056      0.028      0.007     0.128    15.0 
BET14C041   14     41/0100    0.072      0.028      0.007     0.144    21.0 
BET12C065   12     65/0100    0.088      0.028      0.007     0.161    29.5 
BET10C105   10    105/0100    0.115      0.032      0.015     0.223    50.5 
BET08C133    8    133/0111    0.164      0.032      0.015     0.260    74.5 
BET06C133    6    133/0140    0.206      0.032      0.015     0.305   108.5 
BET04C133    4    133/0177    0.262      0.032      0.015     0.361   181.5 
BET02C259    2    259/0160    0.336      0.035      0.020     0.447   247.0 
BET01C259    1    259/0177    0.378      0.035      0.020     0.489   309.0 
BETX1C259  1/0    259/0202    0.422      0.035      0.020     0.538   386.0 
BETX2C259  2/0    259/0227    0.477      0.035      0.020     0.591   473.0 
BETX3C259  3/0    259/0255    0.533      0.035      0.020     0.648   594.0 
BETX4C259  4/0    259/0286    0.601      0.035      0.020     0.714   734.0 
All Dimensions are Nominal.

Also Available in Multi-Conductor Constructions.
Please Contact Our Factory for Sizes or Information Not Listed.
All material included in this bulletin is advisory only and its use by anyone is entirely voluntary. Information herein is believed to be accurate as of publication date, however, if errors exist they are unintentional and Radix is not responsible for any claim traceable to such an error. For applications that require tight tolerances, please contact the Radix factory for dimensional verification. Reliance upon the contents of this bulletin for any purpose by anyone is at the sole risk of that person and Radix Wire Co. Inc. is not responsible for any loss, claim or damage arising therefrom. Information contained in this bulletin is subject to change without notice. All users are cautioned that any UL and CSA approvals referenced in this publication may be revised or withdrawn at any time. Interested persons may receive current information concerning the status of any listing by contacting the appropriate listing body: UL or CSA.


Complete our application questionnaire for a free quote.


Features | Construction | Specifications

©1999 Radix Wire Company
Problems? Contact our webmaster.