FEP HIGH TEMPERATURE CONTROL CABLE 600 VOLT Effective 2/99 |
Part Number Conductor Insulation Jacket Nominal Approx.
Number of Diameter Thickness Thickness Diameter Weight
Cond. (In) (In) (In) (In) (Lbs/Mft)
18 AWG, 7 Strand
FQ18AT02A 2 0.045 0.015 0.012 0.192 24.7
FQ18AT03A 3 0.045 0.015 0.012 0.204 33.6
FQ18AT04A 4 0.045 0.015 0.012 0.222 42.3
FQ18AT05A 5 0.045 0.015 0.012 0.246 53.9
FQ18AT07A 7 0.045 0.015 0.012 0.269 70.2
FQ18AT09A 9 0.045 0.015 0.015 0.322 98.2
FQ18AT12A 12 0.045 0.015 0.015 1.364 125.8
16 AWG, 7 Strand
FQ16AT02A 2 0.056 0.015 0.012 0.212 32.6
FQ16AT03A 3 0.056 0.015 0.012 0.228 46.0
FQ16AT04A 4 0.056 0.015 0.012 0.248 58.4
FQ16AT05A 5 0.056 0.015 0.015 0.282 77.0
FQ16AT07A 7 0.056 0.015 0.015 0.308 100.6
FQ16AT09A 9 0.056 0.015 0.015 0.362 136.1
FQ16AT12A 12 0.056 0.015 0.015 0.409 175.9
14 AWG, 7 Strand
FQ14AT02A 2 0.072 0.015 0.012 0.246 51.6
FQ14AT03A 3 0.072 0.015 0.012 0.262 65.0
FQ14AT04A 4 0.072 0.015 0.015 0.293 85.9
FQ14AT05A 5 0.072 0.015 0.015 0.325 109.4
FQ14AT07A 7 0.072 0.015 0.015 0.356 144.0
FQ14AT09A 9 0.072 0.015 0.015 0.419 195.6
FQ14AT12A 12 0.072 0.015 0.020 0.484 247.4
12 AWG, 7 Strand
FQ12AT02A 2 0.088 0.015 0.015 0.282 67.0
FQ12AT03A 3 0.088 0.015 0.015 0.303 95.6
FQ12AT04A 4 0.088 0.015 0.015 0.334 124.1
FQ12AT05A 5 0.088 0.015 0.015 0.368 156.8
FQ12AT07A 7 0.088 0.015 0.015 0.404 154.7
FQ12AT09A 9 0.088 0.015 0.020 0.487 287.4
FQ12AT12A 12 0.088 0.015 0.020 0.554 360.2
All Dimensions are Nominal.
Please Contact Our Factory for Sizes or Information Not Listed.
|
|
|
All material included in this bulletin is advisory only and its use by anyone is entirely voluntary. Information herein is believed to be accurate as of publication date, however, if errors exist they are unintentional and Radix is not responsible for any claim traceable to such an error. For applications that require tight tolerances, please contact the Radix factory for dimensional verification. Reliance upon the contents of this bulletin for any purpose by anyone is at the sole risk of that person and Radix Wire Co. Inc. is not responsible for any loss, claim or damage arising therefrom. Information contained in this bulletin is subject to change without notice. All users are cautioned that any UL and CSA approvals referenced in this publication may be revised or withdrawn at any time. Interested persons may receive current information concerning the status of any listing by contacting the appropriate listing body: UL or CSA.
Complete our application questionnaire for a free quote. ©1999 Radix Wire Company Problems? Contact our webmaster. |
|